Flow and Volume Measurement


Flow Sensor designed for flow and volume monitoring in Pulmonary Ventilators, CPAP, BIPAP, and Non Invasive Ventilators that allows proximal or distal measurements. It is available for three ranges of flow

  • NEONATE
  • INFANT
  • ADULT

TopoBack to top

Ventilation Monitor


The flow sensor can be easily coupled to any ventilator and it requires two pressure transducers. This allows real time patient ventilation monitoring and the parameters that can be measured are:

  • Flow x Time Curve ;
  • Volume x time Curve;;
  • Pressure x Time Curve;
  • Volume x Pressure Loop;
  • Flow x Volume Loop;
  • Airway Resistence (Raw) ;
  • Static Pulmonary Compiance (Csta)
  • Dynamic Pulmonary Compliance (Cdyn);
  • Peak Pressure;
  • Plateau Pressure;
  • PEEP / CPAP;
  • Mean Pressure;
  • Minute Volume;
  • Tidal Volume;
  • Respiration Rate;
  • Inspiratory Time;
  • Expiratory Time;
  • I:E Ratio;
  • Work of Breathing;
  • P0.1;
  • Tobin Index

It also can be used internally to a ventilator pneumatics in order to control the inspiratory and expiratory flow.

Another important application is for continuous flow measurements to determine the correct time to swap from inspiratory phase to expiratory phase in Pressure Support Ventilation (PSV).

TopoBack to top

Accuracy and Reliability


  • Lightweight: less than 9.0 grams
  • Designed for Medical Applications
  • Dead Space less than 2mL
  • Small Size
  • Standard Connection 15M e 15F/22M
  • Compatible Medical Gases: O2, N2O, Ar, CO2, Heliox, NO
  • Bidirectional Measurement
  • Measurement Port Polarized
  • Proximal Measurement Compatible

TopoBack to top

Sensor com Linha

Accessories


Flow Sensors, Silicone Connector with Bifilar Line, Disposable Polarized Bifilar Line in PVC.

TopoBack to top

Technical Specifications


Compatible Medical Gases

O2, N2O, NO, CO2, Ar, Heliox

Dead Space

< 2.0 mL

Weight

< 9.0 gramas

Neonate Maximum Flow

20 L/min @ 10 cmH2O

Infant Maximum Flow

50 L/min @ 10 cmH2O

Adult Maximum Flow

160 L/min @ 10 cmH2O

Respiratory Circuit Connector

15M & 15F/22M

Sterilizable (Polycarbonate)

Chemical or Gamma Radiation

Autoclavablel (Poyisulfone)

96 KPa, 120 ºC, 15 min

TopoBack to top

Additional Resources


Brochure

Flow Sensor

Ordering Information

Code
Description
Notes
5001493

Neonate Flow Sensor Autoclavable
05 sensors with silicone line
5001494

Infant Flow Sensor Autoclavable
05 sensors with silicone line
5001495

Adult Flow Sensor Autoclavable
05 sensors with silicone line
5001496
Neonate Flow Sensor Sterilizable
05 sensors with PVC line
5001497

Adult Flow Sensor Sterilizable
05 sensors with PVC line
5001498
Adult Flow Sensor Sterilizable
05 sensors with PVC line

TopoBack to top

For additional information on Flow Sensors, please contact us online or at the following number:

BRAZIL - Sao Paulo +55 11 5081-4115
   

TopoBack to top


MAGNAMED TECNOLOGIA MÉDICA S.A.
Rua São Paulino, 221 Vila Mariana
São Paulo - SP - Brasil CEP:04019-040
Tel/Fax:+55(11) 5081-4115
e-mail: magnamed@magnamed.com.br
©2005 - 2010 Direitos Reservados

Invested by:

20091014TUV-NORD_ISO13485
20091014BRTUV_ISO9001
Criatec